Smart Vent
Technical Parameters | ||||
Model | AC 160 | AC 260 | AC 360 | AC 500 |
Size | ||||
Power | 18W | 58W | 105W | 170W |
PTC Power | 1080W | 1120W | 1200W | 1300W |
Coverage | 65m² | 120m² | 150m² | <200m² |
| ||||
PM2.5 single passthrough purification efficiency | >99.99% | >99.99% | >99.99% | >99.99% |
Noise on highest operation level | 29.6db | 35.2db | 37.3db | 42.8db |
Noise on lowest operation level | <22.1db | <22.1db | <22.1db | <22.1db |
Minimum wind volume | 100m³/h | 105m³/h | 110m³/h | / |
Maximum wind volume | 220m³/h | 320m³/h | 440m³/h | 500m³/h |
Wind outlet position | Upper outlet (Vertical mounting) | Upper outlet (Vertical mounting) | Upper outlet (Vertical mounting) | Upper outlet (Vertical mounting) |
| ||||
First filter Layer | Washable PreFilter | Washable PreFilter | Washable PreFilter | Washable PreFilter |
Second filter layer | F9 Medium Filter | G4 Coarse PreFilter | G4 Coarse PreFilter | G4 Coarse PreFilter |
Third filter layer | TVOC Filter | F9 Medium Filter | F9 Medium Filter | F9 Medium Filter |
Fourth filter layer | - | TVOC Filter | TVOC Filter | TVOC Filter |
Fifth filter (efficient filter) | H13/14 HEPA Filter | H13/14 HEPA Set Filter | H13/14 HEPA Cartridge Filter | H13/14 HEPA Cartridge Filter |
* Filter life expectancy is based on the Airproce laboratory testing, under the environment of 10 operation hours per day & level-3 fan speed. The actual filter life depends on user environment, actual operating fan speed and operation time. Thus, the recommended service life is for reference only. | ||||
| ||||
Air condition monitor function | PM2.5 monitoring, CO2 monitoring, | PM2.5 monitoring, CO2 monitoring, | PM2.5 monitoring, CO2 monitoring, | PM2.5 monitoring, CO2 monitoring, |
Screen | 5.1 inch lattice screen | 5.1 inch lattice screen | 5.1 inch lattice screen | 5.1 inch lattice screen |
Operation mode | Manual mode / smart constant oxygen mode / sleep mode | Manual mode / smart constant oxygen mode / sleep mode | Manual mode / smart constant oxygen mode / sleep mode | Manual mode / smart constant oxygen mode / sleep mode |
Installation | Vertical mounting / Wall mounting (side outlet hole) / Wall mounting (back outlet hole) / Wall mounting (bottom outlet hole) / Concealed mounting | Vertical mounting / Wall mounting (side outlet hole) / Wall mounting (back outlet hole) / Wall mounting (bottom outlet hole) / Concealed mounting | Vertical mounting / Wall mounting (side outlet hole) / Wall mounting (back outlet hole) / Wall mounting (bottom outlet hole) / Concealed mounting | Vertical mounting / Wall mounting (side outlet hole) / Wall mounting (back outlet hole) / Wall mounting (bottom outlet hole) / Concealed mounting |